Home > GENERATORS > Standby Generators > Pramac 30KW Yanmar Industrial Diesel Generator 1800 RPM, Watercooled, Soundproof Enclosed, Automatic Panel w/Breaker #GSW35Y
Pramac 30KW Yanmar Industrial Diesel Generator 1800 RPM, Watercooled, Soundproof Enclosed, Automatic Panel w/Breaker #GSW35Y
|
|
MSRP: $15,439.00
Price: CALL TO ORDER $12,995.00!
Item Number: GSW35Y
Manufacturer: Pramac
Item Condition: BRAND NEW
PRODUCT OPTIONS
* denotes required field
Add Express Shipping For Faster Delivery?*
Add Liftgate Service For Easy Unloading?*
|
SAVE OVER $2,400!
Main features
| Rated prime power (PRP)
|
:
|
31 kW
|
| Voltage
|
:
|
480, 277 V
|
| Voltage
|
:
|
208, 120 V
|
| Voltage
|
:
|
240, 120 V
|
| Frequency
|
:
|
60 Hz
|
| Engine manufacturer
|
:
|
Yanmar
|
| Fuel
|
:
|
Diesel
|
| Engine governor
|
:
|
Mechanical
|
GSW Series - Yanmar
The GSW Series provides the most professional way to fulfill power requirements with highest reliability and excellent performance.
Pramac 30KW Yanmar Industrial Diesel Generator 1800 RPM, Watercooled, Soundproof Enclosed, Automatic Panel w/Breaker #GSW35Y
| Rated prime power (PRP)
|
31 kW
|
|
|
39 kVA
|
| Emer Power (LTP)
|
32 kW
|
|
|
40 kVA
|
| Voltage
|
480, 277 V
|
| Frequency
|
60 Hz
|
| Power factor
|
0,8 cosPhi
|
|
| Rated prime power (PRP)
|
29 kW
|
|
|
36 kVA
|
| Emer Power (LTP)
|
30 kW
|
|
|
37 kVA
|
| Voltage
|
208, 120 V
|
| Frequency
|
60 Hz
|
| Power factor
|
0,8 cosPhi
|
|
| Rated prime power (PRP)
|
20 kW
|
|
|
20 kVA
|
| Emer Power (LTP)
|
22 kW
|
|
|
22 kVA
|
| Voltage
|
240, 120 V
|
| Frequency
|
60 Hz
|
| Power factor
|
1 cosPhi
|
|
| Engine manufacturer
|
Yanmar
|
| Model
|
4TNV98
|
| Fuel
|
Diesel
|
| Exhaust emission
|
EPA Tier 4
|
| Cooling system
|
Water
|
| Nominal operating speed
|
1800 rpm
|
| Displacement
|
202,5 cu inches
|
| Number of cylinders and disposition
|
4, inline
|
| Aspiration
|
Natural
|
| Power (PRP)
|
55 bhp
|
| Power (LTP)
|
60 bhp
|
| Fuel consumption (III) at 75% PRP
|
2,19 gal/h
|
| Fuel consumption (III) at 100% PRP
|
2,91 gal/h
|
| Specific fuel consumption at PRP
|
0,363 lb/hph
|
| Engine governor
|
Mechanical
|
|
| Alternator specifications
|
| Alternator manufacturer
|
Stamford
|
| Model
|
BCI 184H
|
| Power at 27°C (480 V)
|
39 kWE
|
|
|
49 kVA
|
| Power at 27°C (208 V)
|
37 kWE
|
|
|
46 kVA
|
| Power at 27°C (240 V)
|
21 kWE
|
|
|
26 kVA
|
| Insulation class
|
H
|
| Protection grade
|
IP 23
|
| Voltage regulation system
|
Electronic, 1,5%
|
|
| Fuel tank capacity
|
21,00 gal
|
| Autonomy (III) at 75% PRP
|
9,6 h
|
| Autonomy (III) at 100% PRP
|
7,2 h
|
|
|
Length
|
78,70 in
|
|
Width
|
36,22 in
|
|
Height
|
51,22 in
|
|
Weight (dry)
|
2.098,80 lb
|
|
| Automatic control panel (ACP)
|
| Description
|
Automatic control panel mounted on the genset, complete with digital control unit AC01 for monitoring, control and protection of the generating set.
|
|
| Automatic control panel (ACP): digital instrumentation
|
| Generator set voltage (3 phases)
|
Yes
|
| Mains voltage
|
Yes
|
| Generator set frequency
|
Yes
|
| Generator set current (3 phases)
|
Yes
|
| Battery voltage
|
Yes
|
| Power (kW - kVA - kVAr)
|
Yes
|
| Power factor
|
Yes
|
| Hour counter
|
Yes
|
| Engine rpm
|
Yes
|
| Fuel level (%)
|
Yes
|
| Engine temperature
|
Yes
|
|
| Automatic control panel (ACP): commands and other features
|
| Setting: Automatic test
|
Yes
|
| Setting: Automatic starting
|
Yes
|
| Setting: Engine locked
|
Yes
|
| Setting: Mains contactor forced
|
Yes
|
| Setting: Manual start
|
Yes
|
| Setting: Genset contactor forced
|
Yes
|
| Emergency stop button
|
Yes
|
| Remote start capable
|
Yes
|
| Acoustic alarm
|
Yes
|
| Integrated battery charger
|
Yes
|
|
| Automatic control panel (ACP): protections with alarm
|
| Engine protection: low fuel level
|
Yes
|
| Engine protection: low oil pressure
|
Yes
|
| Engine protection: high engine temperature
|
Yes
|
| Genset protection: start failure
|
Yes
|
| Genset protection: under/over voltage
|
Yes
|
| Genset protection: under/over frequency
|
Yes
|
| Genset protection: under/over battery voltage
|
Yes
|
| Genset protection: battery charge failure
|
Yes
|
| Genset protection: overload
|
Yes
|
|
| Automatic control panel (ACP): protections with shutdown
|
| Circuit bracker and differential protection
|
Optional
|
| Engine protection: low fuel level
|
Yes
|
| Engine protection: high engine temperature
|
Yes
|
| Engine protection: low oil pressure
|
Yes
|
| Genset protection: under/over voltage
|
Yes
|
| Genset protection: overload
|
Yes
|
| Genset protection: under/over battery voltage
|
Yes
|
| Genset protection: battery charge failure
|
Yes
|
|
| Automatic control panel (ACP): output features
|
| Power cable connected to terminals board (external)
|
Yes
|
| Main lugs
|
Yes
|
|

|
|
_____________________
_____________________
ENGINE CATALOGS
|
|